Electrical Safety Check
Construction
AB Electrical
0Downloads
Share This Template

Audit

General

Type of installation
Search and select all that apply
Upload images or videos to this field
Drag and Drop or Upload
Approximate age of installation
Search and select all that apply
Upload images or videos to this field
Drag and Drop or Upload
Evidence of additions or alterations.
Yes
No
N/A
Upload images or videos to this field
Drag and Drop or Upload
If "yes", estimated age.
0-5 years
5-10 years
10-15 years
15-20 years
20-25 years
Upload images or videos to this field
Drag and Drop or Upload

Consumer Mains

Identification of cable cores.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Current carrying capacity.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Voltage Drop.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Aerial installation conditions.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Connection of wiring.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload

Switchboards

Location. e.g. Not in restricted location, access and egress.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
MEN connection Intact.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Basic protection against contact with live parts. e.g. insulation and enclosures.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Protection against the spread of fire.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Protection devices installed and suitably rated for over-current protection, arc fault protection and discrimination.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Connecting devices. e.g. earth bar, neutral and active links.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Connection and fixing of wiring and switchgear.
Yes
No
N/A
Upload images or videos to this field
Drag and Drop or Upload
Identification and labelling of electrical equipment. e.g. switchboard markings and circuit identification
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Protection against external influences. e.g. mechanical damage, effects of UV light.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Isolating devices e.g. main switches.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Fault protection (protection against indirect contact with live parts) by the use of automatic disconnection of supply. Check that the consumer mains have over current protection.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
RCD's installed on applicable circuits.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload

Wiring Systems

Conductor Size. Check current carrying capacity and derating of cables.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Identification of cable cores.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Support and fixings.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Connections and enclosures. Check to confirm that cables are suitably terminated.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Overhead wiring systems. Check clearances from structures, vegetation and ground.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Segregation from other services. Gas, water, solar.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Protection against external influences. e.g. mechanical damage, effects of UV light.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Installation of cables in accessible areas of the ceiling space. e.g. near manhole, crossing roof battens and trusses.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload

Electrical Equipment

General condition of electrical equipment.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Isolation devices installed where required.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Down lights installed in accordance with AS/NZS 3000:2007.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Equipment installed as per manufacturers requirements.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Fixing and support of equipment adequate
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Equipment suitable for the operating environment. e.g. IP rating.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Protection against hazardous parts. e.g. guarding, screening etc.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Availability of user manuals, operating instructions.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload

Earthing

Earth electrode installed. Sign and tag attached to main earthing conductor.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Earthing conductors. e.g. size, identification.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Equipotential bonding conductors. Pool fences, water piping, slab reinforcing wet areas
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Connection, joints and terminations adequate.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Protection against external influences. e.g. mechanical damage, effects of UV light.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Conductive building materials connected to earth where required. e.g. contact with single insulated cables.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload
Creation of an earthed situation that may require earthing of additional electrical equipment.
Compliant
Non Compliant
Not Assessed
Upload images or videos to this field
Drag and Drop or Upload

General Condition of electrical installation

Please state:
Pass
Fail
Upload images or videos to this field
Drag and Drop or Upload

Exit Checks

MEN connection intact
Yes
No
N/A
Upload images or videos to this field
Drag and Drop or Upload
Switchboard secure.
Yes
No
N/A
Upload images or videos to this field
Drag and Drop or Upload
Main switch and circuit protection returned to original state.
Yes
No
N/A
Upload images or videos to this field
Drag and Drop or Upload
Tools and equipment returned to vehicle.
Yes
No
N/A
Upload images or videos to this field
Drag and Drop or Upload
Person in control advised of departure.
Yes
No
N/A
Upload images or videos to this field
Drag and Drop or Upload